About 9 to 12 hours for a typical 23,000 BTU heater, which holds just under 2 gallons. That is about 6 hours a gallon at full output. A smaller heater burns less and runs longer.
These figures come from the owner’s manuals of three Comfort Glow heaters:
| Heater | Heat output | Tank | Run time on a tank | Burns at most |
|---|---|---|---|---|
| KW-24J, convection | 23,800 BTU an hour | 1.9 gallons | About 9 to 12 hours | 0.18 gallons an hour |
| KW-12A, convection | 10,500 BTU an hour | 1.1 gallons | About 12 to 15 hours | 0.079 gallons an hour |
| KW-11G, radiant | 10,000 BTU an hour | 1 gallon | About 11 to 14 hours | 0.07 gallons an hour |
A smaller heater gets about twice the hours from each gallon. It also fits a smaller room: the manuals say never to run a heater where there is less than 200 cubic feet of air for each 1,000 BTU. With 8-foot ceilings that is about 600 square feet of floor for the 23,800 BTU heater, and about 250 for a 10,000 BTU one.
| Heater | Hours on 1 gallon | Hours on 5 gallons | Days at 8 hours a day |
|---|---|---|---|
| 23,800 BTU, at full output | About 5½ | About 28 | About 3½ |
| 10,500 BTU | About 12½ | About 63 | About 8 |
| 10,000 BTU | About 14 | About 71 | About 9 |
That is our arithmetic from each manual’s burn rate. Turned down, a heater burns less. Kerosene holds about 135,000 BTU a gallon (US Energy Information Administration).
A kerosene heater burns fuel in the room you are sitting in. The Consumer Product Safety Commission’s rules:
Not everywhere. The National Fire Protection Association: “Portable kerosene heaters are illegal in some communities. Check with your local fire department before using.”
Kerosene is sold as paraffin in the UK. The UK government’s winter fire safety advice says to use gas or paraffin heaters only in well-ventilated areas, and to fit a carbon monoxide alarm in every room with a fuel-burning appliance.
MyPlann plans about 6 hours of heat from a gallon of kerosene in a 23,000 BTU heater, and a day of heat as the hours you told us you run it, or 8 if you haven’t said. So 5 gallons is about 30 hours: almost 4 days at 8 hours a day. Heat is one of five things MyPlann counts days for, with water, food, cooking fuel and medicine.
For the rest of staying warm, see how to stay warm without power.
MyPlann counts days for water, food, cooking fuel, heat and medicine from what is actually in your house, and tells you which runs out first. Get your number; it is free during early access.